Link Suppressed Tasks to Tasks

Purpose

Select the Tasks that must be suppressed by the current Task.

Before you start

The Suppressed Task must be added to the Component, Asset Type or Asset before it is linked to another Task for the same Component, Asset Type or Asset.

How to… Link Suppressed Tasks to a Task

1.   Click the Follow up and Suppressed Tasks button in the toolbar on the edit window.
The Follow up and Suppressed Tasks for Asset Task or Asset Type Task window opens.

2. Select the Suppressed tasks tab

3.   Click +.
The Suppressed Tasks lookup window opens.

4.   Select the Task that must be suppressed when the current Task is scheduled.

5.   Save the record.

6.   Repeat from step 2 for each additional suppressed Task.

Data fields

Refer to Tasks - Suppressed Tasks.

Business rules

Please note!

Example

A Task 1011 “Tighten all electrical connections” is performed every 28 days, and another Task 1020 “Check all electrical connections” is performed every 7 days.

Task 1011 includes Task 1020 so Task 1020 “Check all electrical connections” is suppressed by Task 1011 “Tighten all electrical connections”.

Example

The following example illustrates the calculation that is used depending on the value of Num Cycles Suppressed on the Task - Suppressed Tasks Tab, and when the Asset Task is scheduled to be performed.

 

Scenario 1

Scenario 2

Scenario 3

Scenario 4

T1: Interval

3000 hrs

3000 hrs

3000 hrs

3000 hrs

T1: 1st time

2900 hrs

2900 hrs

3100 hrs

3100 hrs

T1: 2nd time

5900 hrs

5900 hrs

6100 hrs

6100 hrs

T2: Interval

6000 hrs

6000 hrs

6000 hrs

6000 hrs

T2: first time

6000 hrs

6000 hrs

6000 hrs

6000 hrs

T2: Suppressed Task

T1

T1

T1

T1

T2: Num Cycles Suppressed

0

0.1

0

0.1

T2: Suppression %

50%

50%

50%

50%

Suppression range calculation

[T2: Interval - (T1: Interval * Suppression %)

[T2: Interval + (T1: Interval * Num Cycles Suppressed)

[T2: Interval - (T1: Interval * Suppression %)

[T2: Interval + (T1: Interval * Num Cycles Suppressed)

 

[6000 - or + (3000*0.5)

[6000 + (3000*0.1)

[6000 - or + (3000*0.5)

[6000 + (3000*0.1)

Suppression range

4500 - 7500 hrs

6000 - 6300 hrs

4500 - 7500 hrs

6000 - 6300 hrs

Result

T1 is suppressed at 5900hr

 

T1 not suppressed at 5900hr

Suppression % is ignored because Num Cycles Suppressed = 0

T1 is suppressed at 6100hr

 

T1 is suppressed at 6100hr

Suppression % is ignored because Num Cycles Suppressed = 0